In this video, we're going to begin talking about ion exchange chromatography. So ion exchange chromatography is a type of column chromatography that purifies a protein based on the magnitude or the size of its net charge. And, in general, there are 2 main types of ion exchange chromatography. The first is cation exchange chromatography and the second is anion exchange chromatography. And just like we know cations are positively charged, cation exchange chromatography is generally used to purify positively charged proteins. And just like we know anions are negatively charged, anion exchange chromatography is generally used to purify negatively charged proteins. So, it makes it easy to remember in that respect. And so, if we know the overall net charge of our target protein, then ion exchange chromatography can be incredibly useful in our protein purification strategy. And so, first, moving forward, we're going to talk about cation exchange chromatography, and then afterwards, we'll talk about anion exchange chromatography. So, I'll see you guys in our next video.
- 1. Introduction to Biochemistry4h 34m
- What is Biochemistry?5m
- Characteristics of Life12m
- Abiogenesis13m
- Nucleic Acids16m
- Proteins12m
- Carbohydrates8m
- Lipids10m
- Taxonomy10m
- Cell Organelles12m
- Endosymbiotic Theory11m
- Central Dogma22m
- Functional Groups15m
- Chemical Bonds13m
- Organic Chemistry31m
- Entropy17m
- Second Law of Thermodynamics11m
- Equilibrium Constant10m
- Gibbs Free Energy37m
- 2. Water3h 23m
- 3. Amino Acids8h 10m
- Amino Acid Groups8m
- Amino Acid Three Letter Code13m
- Amino Acid One Letter Code37m
- Amino Acid Configuration20m
- Essential Amino Acids14m
- Nonpolar Amino Acids21m
- Aromatic Amino Acids14m
- Polar Amino Acids16m
- Charged Amino Acids40m
- How to Memorize Amino Acids1h 7m
- Zwitterion33m
- Non-Ionizable Vs. Ionizable R-Groups11m
- Isoelectric Point10m
- Isoelectric Point of Amino Acids with Ionizable R-Groups51m
- Titrations of Amino Acids with Non-Ionizable R-Groups44m
- Titrations of Amino Acids with Ionizable R-Groups38m
- Amino Acids and Henderson-Hasselbalch44m
- 4. Protein Structure10h 4m
- Peptide Bond18m
- Primary Structure of Protein31m
- Altering Primary Protein Structure15m
- Drawing a Peptide44m
- Determining Net Charge of a Peptide42m
- Isoelectric Point of a Peptide37m
- Approximating Protein Mass7m
- Peptide Group22m
- Ramachandran Plot26m
- Atypical Ramachandran Plots12m
- Alpha Helix15m
- Alpha Helix Pitch and Rise20m
- Alpha Helix Hydrogen Bonding24m
- Alpha Helix Disruption23m
- Beta Strand12m
- Beta Sheet12m
- Antiparallel and Parallel Beta Sheets39m
- Beta Turns26m
- Tertiary Structure of Protein16m
- Protein Motifs and Domains23m
- Denaturation14m
- Anfinsen Experiment20m
- Protein Folding34m
- Chaperone Proteins19m
- Prions4m
- Quaternary Structure15m
- Simple Vs. Conjugated Proteins10m
- Fibrous and Globular Proteins11m
- 5. Protein Techniques14h 5m
- Protein Purification7m
- Protein Extraction5m
- Differential Centrifugation15m
- Salting Out18m
- Dialysis9m
- Column Chromatography11m
- Ion-Exchange Chromatography35m
- Anion-Exchange Chromatography38m
- Size Exclusion Chromatography28m
- Affinity Chromatography16m
- Specific Activity16m
- HPLC29m
- Spectrophotometry51m
- Native Gel Electrophoresis23m
- SDS-PAGE34m
- SDS-PAGE Strategies16m
- Isoelectric Focusing17m
- 2D-Electrophoresis23m
- Diagonal Electrophoresis29m
- Mass Spectrometry12m
- Mass Spectrum47m
- Tandem Mass Spectrometry16m
- Peptide Mass Fingerprinting16m
- Overview of Direct Protein Sequencing30m
- Amino Acid Hydrolysis10m
- FDNB26m
- Chemical Cleavage of Bonds29m
- Peptidases1h 6m
- Edman Degradation30m
- Edman Degradation Sequenator and Sequencing Data Analysis4m
- Edman Degradation Reaction Efficiency20m
- Ordering Cleaved Fragments21m
- Strategy for Ordering Cleaved Fragments58m
- Indirect Protein Sequencing Via Geneomic Analyses24m
- 6. Enzymes and Enzyme Kinetics13h 38m
- Enzymes24m
- Enzyme-Substrate Complex17m
- Lock and Key Vs. Induced Fit Models23m
- Optimal Enzyme Conditions9m
- Activation Energy24m
- Types of Enzymes41m
- Cofactor15m
- Catalysis19m
- Electrostatic and Metal Ion Catalysis11m
- Covalent Catalysis18m
- Reaction Rate10m
- Enzyme Kinetics24m
- Rate Constants and Rate Law35m
- Reaction Orders52m
- Rate Constant Units11m
- Initial Velocity31m
- Vmax Enzyme27m
- Km Enzyme42m
- Steady-State Conditions25m
- Michaelis-Menten Assumptions18m
- Michaelis-Menten Equation52m
- Lineweaver-Burk Plot43m
- Michaelis-Menten vs. Lineweaver-Burk Plots20m
- Shifting Lineweaver-Burk Plots37m
- Calculating Vmax40m
- Calculating Km31m
- Kcat46m
- Specificity Constant1h 1m
- 7. Enzyme Inhibition and Regulation 8h 42m
- Enzyme Inhibition13m
- Irreversible Inhibition12m
- Reversible Inhibition9m
- Inhibition Constant26m
- Degree of Inhibition15m
- Apparent Km and Vmax29m
- Inhibition Effects on Reaction Rate10m
- Competitive Inhibition52m
- Uncompetitive Inhibition33m
- Mixed Inhibition40m
- Noncompetitive Inhibition26m
- Recap of Reversible Inhibition37m
- Allosteric Regulation7m
- Allosteric Kinetics17m
- Allosteric Enzyme Conformations33m
- Allosteric Effectors18m
- Concerted (MWC) Model25m
- Sequential (KNF) Model20m
- Negative Feedback13m
- Positive Feedback15m
- Post Translational Modification14m
- Ubiquitination19m
- Phosphorylation16m
- Zymogens13m
- 8. Protein Function 9h 41m
- Introduction to Protein-Ligand Interactions15m
- Protein-Ligand Equilibrium Constants22m
- Protein-Ligand Fractional Saturation32m
- Myoglobin vs. Hemoglobin27m
- Heme Prosthetic Group31m
- Hemoglobin Cooperativity23m
- Hill Equation21m
- Hill Plot42m
- Hemoglobin Binding in Tissues & Lungs31m
- Hemoglobin Carbonation & Protonation19m
- Bohr Effect23m
- BPG Regulation of Hemoglobin24m
- Fetal Hemoglobin6m
- Sickle Cell Anemia24m
- Chymotrypsin18m
- Chymotrypsin's Catalytic Mechanism38m
- Glycogen Phosphorylase21m
- Liver vs Muscle Glycogen Phosphorylase21m
- Antibody35m
- ELISA15m
- Motor Proteins14m
- Skeletal Muscle Anatomy22m
- Skeletal Muscle Contraction45m
- 9. Carbohydrates7h 49m
- Carbohydrates19m
- Monosaccharides15m
- Stereochemistry of Monosaccharides33m
- Monosaccharide Configurations32m
- Cyclic Monosaccharides20m
- Hemiacetal vs. Hemiketal19m
- Anomer14m
- Mutarotation13m
- Pyranose Conformations23m
- Common Monosaccharides33m
- Derivatives of Monosaccharides21m
- Reducing Sugars21m
- Reducing Sugars Tests19m
- Glycosidic Bond48m
- Disaccharides40m
- Glycoconjugates12m
- Polysaccharide7m
- Cellulose7m
- Chitin8m
- Peptidoglycan12m
- Starch13m
- Glycogen14m
- Lectins16m
- 10. Lipids5h 49m
- Lipids15m
- Fatty Acids30m
- Fatty Acid Nomenclature11m
- Omega-3 Fatty Acids12m
- Triacylglycerols11m
- Glycerophospholipids24m
- Sphingolipids13m
- Sphingophospholipids8m
- Sphingoglycolipids12m
- Sphingolipid Recap22m
- Waxes5m
- Eicosanoids19m
- Isoprenoids9m
- Steroids14m
- Steroid Hormones11m
- Lipid Vitamins19m
- Comprehensive Final Lipid Map13m
- Biological Membranes16m
- Physical Properties of Biological Membranes18m
- Types of Membrane Proteins8m
- Integral Membrane Proteins16m
- Peripheral Membrane Proteins12m
- Lipid-Linked Membrane Proteins21m
- 11. Biological Membranes and Transport 6h 37m
- Biological Membrane Transport21m
- Passive vs. Active Transport18m
- Passive Membrane Transport21m
- Facilitated Diffusion8m
- Erythrocyte Facilitated Transporter Models30m
- Membrane Transport of Ions29m
- Primary Active Membrane Transport15m
- Sodium-Potassium Ion Pump20m
- SERCA: Calcium Ion Pump10m
- ABC Transporters12m
- Secondary Active Membrane Transport12m
- Glucose Active Symporter Model19m
- Endocytosis & Exocytosis18m
- Neurotransmitter Release23m
- Summary of Membrane Transport21m
- Thermodynamics of Membrane Diffusion: Uncharged Molecule51m
- Thermodynamics of Membrane Diffusion: Charged Ion1h 1m
- 12. Biosignaling9h 45m
- Introduction to Biosignaling44m
- G protein-Coupled Receptors32m
- Stimulatory Adenylate Cyclase GPCR Signaling42m
- cAMP & PKA28m
- Inhibitory Adenylate Cyclase GPCR Signaling29m
- Drugs & Toxins Affecting GPCR Signaling20m
- Recap of Adenylate Cyclase GPCR Signaling5m
- Phosphoinositide GPCR Signaling58m
- PSP Secondary Messengers & PKC27m
- Recap of Phosphoinositide Signaling7m
- Receptor Tyrosine Kinases26m
- Insulin28m
- Insulin Receptor23m
- Insulin Signaling on Glucose Metabolism57m
- Recap Of Insulin Signaling in Glucose Metabolism6m
- Insulin Signaling as a Growth Factor1h 1m
- Recap of Insulin Signaling As A Growth Factor9m
- Recap of Insulin Signaling1m
- Jak-Stat Signaling25m
- Lipid Hormone Signaling15m
- Summary of Biosignaling13m
- Signaling Defects & Cancer20m
- Review 1: Nucleic Acids, Lipids, & Membranes2h 47m
- Nucleic Acids 19m
- Nucleic Acids 211m
- Nucleic Acids 34m
- Nucleic Acids 44m
- DNA Sequencing 19m
- DNA Sequencing 211m
- Lipids 111m
- Lipids 24m
- Membrane Structure 110m
- Membrane Structure 29m
- Membrane Transport 18m
- Membrane Transport 24m
- Membrane Transport 36m
- Practice - Nucleic Acids 111m
- Practice - Nucleic Acids 23m
- Practice - Nucleic Acids 39m
- Lipids11m
- Practice - Membrane Structure 17m
- Practice - Membrane Structure 25m
- Practice - Membrane Transport 16m
- Practice - Membrane Transport 26m
- Review 2: Biosignaling, Glycolysis, Gluconeogenesis, & PP-Pathway3h 12m
- Biosignaling 19m
- Biosignaling 219m
- Biosignaling 311m
- Biosignaling 49m
- Glycolysis 17m
- Glycolysis 27m
- Glycolysis 38m
- Glycolysis 410m
- Fermentation6m
- Gluconeogenesis 18m
- Gluconeogenesis 27m
- Pentose Phosphate Pathway15m
- Practice - Biosignaling13m
- Practice - Bioenergetics 110m
- Practice - Bioenergetics 216m
- Practice - Glycolysis 111m
- Practice - Glycolysis 27m
- Practice - Gluconeogenesis5m
- Practice - Pentose Phosphate Path6m
- Review 3: Pyruvate & Fatty Acid Oxidation, Citric Acid Cycle, & Glycogen Metabolism2h 26m
- Pyruvate Oxidation9m
- Citric Acid Cycle 114m
- Citric Acid Cycle 27m
- Citric Acid Cycle 37m
- Citric Acid Cycle 411m
- Metabolic Regulation 18m
- Metabolic Regulation 213m
- Glycogen Metabolism 16m
- Glycogen Metabolism 28m
- Fatty Acid Oxidation 111m
- Fatty Acid Oxidation 28m
- Citric Acid Cycle Practice 17m
- Citric Acid Cycle Practice 26m
- Citric Acid Cycle Practice 32m
- Glucose and Glycogen Regulation Practice 14m
- Glucose and Glycogen Regulation Practice 26m
- Fatty Acid Oxidation Practice 14m
- Fatty Acid Oxidation Practice 27m
- Review 4: Amino Acid Oxidation, Oxidative Phosphorylation, & Photophosphorylation1h 48m
- Amino Acid Oxidation 15m
- Amino Acid Oxidation 211m
- Oxidative Phosphorylation 18m
- Oxidative Phosphorylation 210m
- Oxidative Phosphorylation 310m
- Oxidative Phosphorylation 47m
- Photophosphorylation 15m
- Photophosphorylation 29m
- Photophosphorylation 310m
- Practice: Amino Acid Oxidation 12m
- Practice: Amino Acid Oxidation 22m
- Practice: Oxidative Phosphorylation 15m
- Practice: Oxidative Phosphorylation 24m
- Practice: Oxidative Phosphorylation 35m
- Practice: Photophosphorylation 15m
- Practice: Photophosphorylation 21m
Ion-Exchange Chromatography - Online Tutor, Practice Problems & Exam Prep
Ion exchange chromatography is a column chromatography technique used to purify proteins based on their net charge. Cation exchange chromatography targets positively charged proteins using a negatively charged stationary phase, typically composed of carboxymethyl (CM) functional groups. During the process, loosely bound cations are exchanged with the target proteins, allowing for effective separation. Negatively charged proteins elute first, followed by neutral proteins, while positively charged proteins remain bound, facilitating their purification. Salt can be added to elute these proteins by weakening ionic interactions, enhancing the efficiency of the purification process.
Ion-Exchange Chromatography
Video transcript
Ion-Exchange Chromatography
Video transcript
So in general, ion exchange chromatography can sometimes be a little bit counterintuitive with all the different charges that we have going on. So in this video, we're going to break down cation exchange chromatography to make sure we understand how it works. And so, in our last lesson video, we said that just like cations are positively charged, cation exchange chromatography is used to collect and purify positively charged proteins. And so, in order to collect and purify positively charged proteins, cation exchange chromatography needs to use a negatively charged stationary phase or a negatively charged stationary resin, and resins are just the little beads that make up the stationary phase. An example of a negatively charged stationary resin are resins that have carboxymethyl functional groups attached, or just CM groups for short, for carboxymethyl. And so, all I want you guys to know is that CM groups are a type of negatively charged stationary resin used in cation exchange chromatography.
If we take a look at our example down below, what we'll see is that we've got our columns because we know ion exchange chromatography is a type of column chromatography. And so, inside our columns, we know that we have our stationary phase, so we can see our blue stationary phase inside all of our columns here. Notice that our stationary phase is made up of a bunch of beads or a bunch of resin, these circular things. And if we zoom in on one of them, what we'll see is that it's really like carboxymethyl functional groups that are attached, and they are negatively charged. Notice that we have all of these negative charges on our stationary phase. And then, what you'll also notice is that, before the cation exchange process even begins, what happens is we actually have these cations such as sodium ions that are loosely bound to the negatively charged resin. And so we can see that down below, we have these positively charged sodium cations that are very weakly bound to the negatively charged stationary resin. And so, these cations are there before we even begin the process. And so the reason that we call it cation exchange chromatography is because these loosely bound cations, during the process, they're actually exchanged with our target protein. The cations are exchanged with our target protein, and our target protein is going to be the one that we're trying to purify, which we know is going to be positively charged for cation exchange chromatography. And so that's exactly why it's called cation exchange chromatography, because cations are exchanged with the target protein.
To be able to figure out how cation exchange chromatography works, what we need to know is that positively charged proteins that we're interested in purifying, they actually bind to the negatively charged stationary resin. And if they bind to the stationary phase, which we know the stationary phase does not move, that means that the positively charged proteins are going to be less likely to move, so they are essentially not going to move as much as all of the other molecules in the column. So, you can think of them as being stuck inside the column. And so that means that the neutral or the negatively charged proteins, on the other hand, they are not going to interact with the stationary resin negatively charged, and they're going to pass right through. They literally just flow straight through the column and go through very quickly. And so, the greater the net negative charge on the protein, the faster and the earlier the protein will come out of the column. And remember, these are the unwanted proteins, because the ones that we're trying to collect and purify, which are the positively charged ones, are going to remain stuck inside the column, and it's only the ones that we don't want, the unwanted ones, that end up coming out.
So notice over here in our beaker, what we have is a protein mixture. And inside of our protein mixture, notice that we have these red, positively charged proteins, negatively charged proteins, and then we also have these black or gray, neutral proteins. And so we have a mixture of proteins with a bunch of different charges. And so if we take our protein mixture here and we pour it into our cation exchange chromatography column, essentially, what we will have is our mixture of proteins at the very top. And then we have our mobile phase inside of this container, at the top, and we know that we're going to be continuously adding the mobile phase throughout the entire process. And so, as we start to add more and more mobile phase, eventually what's going to happen is we're going to get separation of this protein mixture based on the charges of the proteins. With a cation exchange chromatography column, the negatively charged proteins do not interact with the negatively charged resin, and they come out of the column the fastest, and that's why we see them at the bottom. The neutral proteins, they come out next, so they come out the next fastest.
Down here at the bottom, what we can say is that it's the negatively charged proteins that are actually eluted from the column first, or come out of the column first before any of the other proteins. And so notice that throughout this entire process, the positively charged proteins are actually moving in the column, but they move much, much slower, and that's because the positively charged proteins are interacting with the negatively charged stationary resin. Even though they move through the column, they move incredibly slowly through the column, and that's what we're seeing. Positively charged proteins move incredibly slowly through the column. And so the proteins that move the slowest are going to be the ones that have the greatest positive charge because they interact with the negatively charged stationary phase the strongest. And the ones that, the positively charged proteins that move the fastest, they have a positive charge, but they just have a small positive charge. And so, they move through a little bit faster because they don't interact as strong with the negatively charged stationary phase. And so, the reason that we want to use cation exchange chromatography to collect and purify positively charged proteins and not negatively charged proteins is that, when we have our proteins that are stuck inside the column like this, they have more interactions with the stationary phase and with the mobile phase because we're continuously adding mobile phase the whole time. And so the more interactions you have with the stationary phase and the mobile phase, the better the separation is going to be. And so, if we're trying to collect and purify our target protein, we want to have incredibly good separation. And so we'll get better separation of positively charged proteins using a cation exchange chromatography column. And so, that explains why we want to use cation exchange chromatography for positively charged proteins.
And so, you might be wondering, how do we get these positively charged proteins out of the column? Now that we've gotten rid of all of these other proteins here, how do we collect these positively charged proteins? Now, we could continuously add more and more mobile phase, but that might take a long time because of how strong these interactions are with the negatively charged stationary phase. And so another way to be able to quickly get out our positively charged proteins is to elute our proteins later from our column, with the addition of salt. And so, we know from salting out, our salting-out topic in our previous lessons, that salts are able to reduce and decrease the strength of the ionic interactions. And so if we add salt, it's going to decrease the strength of the ionic interactions that hold the positively charged protein to the negatively charged stationary resin. And then that means that all of the positively charged proteins can be eluted quickly.
Down here in our example, what you'll see is that it's asking us which proteins are going to elute first during cation exchange chromatography. And so, we have protein A, which has a net charge of negative 4, and then we have protein B, which has a net charge of positive 2. And so we know that the proteins that elute first from the column are going to be negatively charged proteins. And so, that means that protein A is going to be the one to elute first. So, we can go ahead and highlight A here as our correct answer, give it a check to indicate A here is correct, and then we can cross off option B, which is not correct. So, this concludes our lesson on cation exchange chromatography, and we'll be able to get a lot more practice utilizing all of these concepts in our next practice videos. So, I'll see you guys there.
What is the order of elution of the following proteins from a cation-exchange chromatography column?
Net charges of Proteins: Protein A = +1 Protein B = -2 Protein C = -5 Protein D = +3.
In a cation-exchange column at neutral pH, which peptide would elute last?
Mixtures of amino acids can be analyzed by first separating the mixture into its components through ion exchange chromatography. Certain amino acids placed on a cation-exchange resin containing sulfonate groups (—SO3-) flow down the column slowly because of two factors that influence their movement: (1) ionic attraction between the sulfonate residues on the column and positively charged functional groups on the amino acids, and (2) hydrophobic interactions between amino acid R-groups and the strongly hydrophobic backbone of the polystyrene resin. For each pair of amino acids listed below, circle the amino acid that is eluted first from the cation-exchange column by a buffer at pH 7.
Problem Transcript
Give the order of elution of the following peptides when using cation-exchange chromatography at pH 7.2.
Peptide #1: A-D-G-H-E. Peptide #2: K-L-M-R-A. Peptide #3: M-D-L-I-V. Peptide #4: I-L-R-P-M.
Order of Elution: _______________, _______________, _______________, _______________
(1 st to elute) (Last to elute)
Problem Transcript
Here’s what students ask on this topic:
What is ion exchange chromatography and how does it work?
Ion exchange chromatography is a technique used to purify proteins based on their net charge. It involves a column filled with a stationary phase composed of charged resin beads. There are two main types: cation exchange chromatography, which targets positively charged proteins using a negatively charged stationary phase, and anion exchange chromatography, which targets negatively charged proteins using a positively charged stationary phase. Proteins with the opposite charge to the stationary phase bind to it, while others pass through. By adding a mobile phase or salt, the bound proteins can be eluted and collected.
What is the difference between cation exchange chromatography and anion exchange chromatography?
Cation exchange chromatography targets positively charged proteins using a negatively charged stationary phase, typically composed of carboxymethyl (CM) functional groups. Anion exchange chromatography, on the other hand, targets negatively charged proteins using a positively charged stationary phase, often composed of diethylaminoethyl (DEAE) groups. The choice between the two depends on the net charge of the target protein. In both methods, proteins with the opposite charge to the stationary phase bind to it, allowing for their separation and purification.
How are proteins eluted in ion exchange chromatography?
Proteins are eluted in ion exchange chromatography by gradually changing the conditions within the column. One common method is to increase the concentration of salt in the mobile phase. The salt ions compete with the bound proteins for binding sites on the stationary phase, weakening the ionic interactions and allowing the proteins to be released. Another method is to change the pH of the mobile phase, which can alter the charge of the proteins and the stationary phase, leading to elution. These techniques help in efficiently collecting the target proteins.
What are the applications of ion exchange chromatography in biochemistry?
Ion exchange chromatography is widely used in biochemistry for protein purification, separation of nucleotides, and purification of enzymes. It is particularly useful in isolating proteins with specific charge properties, making it essential in research and pharmaceutical industries. The technique is also employed in water purification, where it removes ions and impurities. Additionally, it is used in the analysis of complex biological samples, helping to identify and quantify various biomolecules based on their charge characteristics.
Why is salt used in ion exchange chromatography?
Salt is used in ion exchange chromatography to elute bound proteins from the stationary phase. The salt ions compete with the proteins for binding sites on the charged resin beads, weakening the ionic interactions that hold the proteins in place. This process, known as salting out, allows the proteins to be released and collected more efficiently. By adjusting the salt concentration, researchers can control the elution process, ensuring that the target proteins are separated and purified effectively.